+86-10-59429575  info@samyontech.com

Petroleum Test Equipment

SY-5208D Petroleum Test Equipment Rapid Equilibrium Closed Cup Flash Point Tester 300W

  • Product ID:Petroleum Test Equipment
  • QQ:
  • Phone: 18500992119
  • Tel: +86-10-59429575
  • Email: info@samyontech.com
  • Time: 2022-09-09 17:11:47

SY-5208D Petroleum Test Equipment Rapid Equilibrium Closed Cup Flash Point Tester 300W

Description
Name: Closed Cup Flash Point Tester Standard: ISO 3679:2015
Measuring Range: -10℃~+100℃ Temperature Resolution: +/-0.1℃
Igniting Device: Electric Igniting Gun Method: Rapid Equilibrium Closed Cup Method
High Light:

SY-5208D Petroleum Test Equipment

,

SAMYON Petroleum Test Equipment

,

300W Closed Cup Flash Point Tester

SY-5208D Rapid Equilibrium Closed Up Flash Point Tester

 

Application:

It is used to determine different kinds of colored paints, oil paints, adhesives, solvents and petroleum products which the closed cup flash point is 0℃~100℃. The SY-5208D is designed based on SY-5208, so the temperature range is larger. Test sample needed is less than 2ml for each time (4ml for solid sample and semi-solid sample). The testing method is as ISO1523 and ISO3679 standard. So it can be widely used by internal customers.

 

Standard:

ISO 3679:2015 Determination of flash no-flash and flash point - Rapid equilibrium closed cup method

ISO 1523:2002 Determination of flash point - Closed cup equilibrium method

 

Parameters:

 

Item Name Details
1 Igniting device Electric igniting gun
2 Flash point measuring range -10℃~+100℃
3 Cooling mode Semiconductor(with cold water cycle at external connection)
4 Precision of determination it meets the standard GB/T 5208
5 Temperature resolution +/-0.1℃
6 Igniting source Gas, LPG (or other civilian fuels)
7 Ambient temperature 5~30℃
8 Maximum power consumption 300W
9 Relative humidity =<80%
10 Power supply AC 220+/-10% V, 50Hz
11 Dimension 490x520x390mm

 

Features:

1. Test sample is less than 2ml for each time (solid sample and semi-solid sample will be 4ml)

2. The instrument adopts semiconductor refrigeration device and external water cooling device. 

3. Designed as per ISO 3679:2015 Determination of flash point - Rapid equilibrium closed cup method. It can realize purpose rapidly and at low temperature.

4. The determination procedure is automatically completed except ignition. Test results can be printed automatically.

 

SY-5208D Petroleum Test Equipment Rapid Equilibrium Closed Cup Flash Point Tester 300W 0